Technical Specifications & Engineering Parameters
| Equipment Category | Intelligent Dual-Channel Flow Computer and Thermal Energy Totalizer |
| Supported Media | Saturated steam, superheated steam, natural gas, compressed air, industrial water, thermal oil |
| Input Channel Capabilities | Dual pulse/frequency inputs (0-10 kHz), 3 analog 4-20mA inputs (Flow, Temp, Pressure) |
| Totalizing Accuracy | ±0.1% F.S. with 64-bit floating point high-precision accumulation |
| Thermal Energy Calculation | Enthalpy and heat energy metering compliant with EN 1434 standards |
| Historical Logging | Hourly, daily, and monthly automatic shift logging and power-failure history retention |
| Alarm & Control | Up to 4 relay outputs (Batch cutoff, flow high/low limit, sensor failure alarm) |
| Signal Retransmission | Two channels of isolated 4-20mA analog output for instantaneous flow / temperature |
| Communication | Dual RS485 ports or RS485 + RS232 with Modbus-RTU protocol |
| Power Supply | AC 90-260V 50/60Hz or DC 24V |
| Enclosure Type | 160×80mm horizontal rack panel cutout with high-contrast VFD / LCD screen |