Thermal Gas Mass Flow Meter

Thermal gas mass flow meter is designed based on the principle of thermal diffusion.The instrument USES the constant temperature difference method to measure the gas accurately.It has the advantages of small volume, high digitization, convenient installation and accurate measurement. Characteristics ● Various gas mass flow measurements ● LCD liquid crystal display ● 220V, 24V power supply ● Split structure, integrated structure
  • Specification

Technical Specifications & Engineering Parameters

Measurement Principle Thermal dispersion principle (Constant temperature differential method)
Flow Unit Direct standard volumetric / mass flow (Nm3/h, kg/h) without external T/P compensation
Installation Type Insertion probe (for large duct DN80 to DN6000) or Inline flanged pipe (DN15 to DN100)
Applicable Gas Compressed air, Oxygen, Nitrogen, Argon, Biogas, Flue gas, Blast furnace gas
Accuracy Class ±1.0% to ±1.5% of reading
Flow Velocity Range 0.1 to 100 Nm/s (Extremely sensitive to low leakages)
Turndown Ratio 100:1 (Ultra-wide measuring span)
Sensor Material 316L Stainless Steel probe with Hastelloy cladding option
Response Time <= 1 s
Output Interface Dual 4-20mA, Pulse, RS-485 Modbus, Optical relay


Contact us

We offer you the highest quality products and the most considerate service.

wx
Telephone: +86 13309630361